Property | Test Method | Requirement |
Physical: | ||
Tensile Strength | ASTM D 638 | 1500 min. |
Elongation (%) | ASTM D 638 | 200 min. |
Specific Gravity | ASTM D 792 | 1.35 max |
Low Temperature Flex (-55° C) | AMS-DTL-23053 | No cracking |
Heat shock (250° C, 4 hrs.) | AMS-DTL-23053 | No cracking |
Heat resistance (175° C, 168 hrs.) | ||
Elongation (%) | ASTM D 638 | 100 min. |
Longitudinal change (%) | AMS-DTL-23053 | +5, -50 |
Secant Modulus (psi) | ASTM D 882 | 2.5 X 104 max |
Electrical: | ||
Dielectric strength (volts/mil) | ASTM D 876 | 500 min. |
Volume resistivity (ohm-cm) | ASTM D 876 | 2.5 X 104 min. |
Chemical: | ||
Corrosion (175° C, 16 hrs.) | UL 224 | No corrosion |
Water absorption (%) | ASTM D 570 | 0.5 max. |
Fluid resistance (23° C, 24 hrs.) | ||
Tensile strength (psi) | AMS-DTL-23053 | 1000 min. |
Flammability | UL 224 VW1 | Pass |
*For reference use only
Nominal Size | ID Minimum (As Supplied) | ID Maximum (After Recovery) | Wall Thickness Nom (After Recovery) | |||
Inches | MM | Inches | MM | Inches | MM | |
3/4″ | .750 | 19.1 | .180 | 4.6 | .045 | 1.14 |
1″ | 1.00 | 25.4 | .260 | 6.6 | .045 | 1.14 |